Thermal/Multi-Function Data Logger Model 51101 series Thermal/Multi-Function Data Logger Model 51101 series Chroma thermal/multi-function data loggers measure temperatures, voltages, and currents
with high accuracy and resolutions. For example, they support 8 types of thermal couples measurement with ITS-90 defined temperature range at 0.5˚C accuracy and 0.01˚C resolution*, while most data loggers in the market are at 1˚C accuracy and 0.1˚C resolution*. Chroma loggers are with 1000VDC channel to channel isolation, which means they can attach thermal couples to objects with high electricity, such as batteries,
solar cells, working PCB, etc., and still get correct data. Many competitors are just
S000139 Battery test & automation solution Quantity: 0 đôi


  •  
  • Thermal/Multi-Function Data Logger Model 51101 series

  • Post on 27-03-2019 08:39:40 PM - 2638 Views
  • Chroma thermal/multi-function data loggers measure temperatures, voltages, and currents
    with high accuracy and resolutions. For example, they support 8 types of thermal couples measurement with ITS-90 defined temperature range at 0.5˚C accuracy and 0.01˚C resolution*, while most data loggers in the market are at 1˚C accuracy and 0.1˚C resolution*. Chroma loggers are with 1000VDC channel to channel isolation, which means they can attach thermal couples to objects with high electricity, such as batteries,
    solar cells, working PCB, etc., and still get correct data. Many competitors are just



Key Features:
  • Models with 8, and 64 channels on-line data recording. Multi-sets linked to a PC for hundreds of channels are doable
  • Support B, E, J, K, N, R, S, and T type
  • thermal couples with ITS-90 defined temperature range
  • Individual channel cold junction compensation with <±0.5˚C accuracy
  • Temperature resolution up to 0.01˚C, error down to (0.01% of reading+0.5˚C)
  • VA-480 voltage adaptor :
    Voltage range ±480VDC ;
    Resolution 1mV ;
    Accuracy 0.1% of reading+1mV
  • VA-10 voltage adaptor :
    Voltage range ±10VDC ;
    Resolution 100uV ;
    Accuracy 0.05% of reading+500uV
  • 1000VDC channel to channel isolation,full protection for testing points with charge and guarantee for accurate measurements
  • Thermal couple open circuit detection 
  • PC-based operation with powerful software for recording and analyzing data
  • 8 channel model is USB powered. No battery or external power supply is required

It is a general requi rement to record temperatures, voltages, currents, and many physics quantities during research, product development, productions, and quality assurance processes. The number of record channels can be a simple one to several complicated set of hundreds. Thermal/multifunction data loggers are prefect solutions
to serve for these measurement and tracking needs.

There are several measurement products in the market to perform such a large-scale and extensive time varying recording. Some are expensive, some are limited in accuracy or resolution, and some have low immunity to interference. Chroma thermal/multi-function data loggers are by far the most cost-effective solutions for versatility, accuracy, tability, and interference immunity among this category.

Chroma thermal/multi-function data loggers measure temperatures, voltages, and currents
with high accuracy and resolutions. For example, they support 8 types of thermal couples measurement with ITS-90 defined temperature range at 0.5˚C accuracy and 0.01˚C resolution*, while most data loggers in the market are at 1˚C accuracy and 0.1˚C resolution*. Chroma loggers are with 1000VDC channel to channel isolation, which means they can attach thermal couples to objects with high electricity, such as batteries,
solar cells, working PCB, etc., and still get correct data. Many competitors are just
malfunctioned or even damaged in those cases. Data retrieve in Chroma loggers are in a parallel architecture, while most of competitors use a sequential multiplexing method. This means data rate per channel is quick and constant for Chroma loggers, while others become much slower when number of channels is bigger.

Us ing Chroma thermal/mul t i-func t ion data loggers, customers get confidence in measured data and high Performance/Cost ratio. Most of all, we can help in certain cases
that our competitors fail, and only Chroma succeeds.

*Thermocouple error excluded. Please see specification list for detail.

 Request for quote. Please Select the items and "Add to Inquiry Cart".

Model Description Inquiry
51101 series Thermal/Multi-Function Data Logger
51101-8 Thermal/Multi-Function Data Logger - 8 channel
51101-64 Thermal/Multi-Function Data Logger - 64 channel
A511000 VA-480 Voltage Adaptor (option)
A511001 IA-3 Current Adaptor (option)
A511002 VA-10 Voltage Adaptor (option)
A511003 8-port sensor card with package
A511004 C8-port sensor card with package
 
     

 

NGOC MINH ISE CO.,LTD
- HCMC Office: Block A, Lever 2, Linh Trung Building, No 6-8, Road no 16, Linh Trung Ward, Thu Duc City, HCMC.
- Head Quaters: 427 Le Dai Hanh, Ward 11, District 11, HCM City.
- Bac Ninh: Road TS5, Tien Son IZ, Tu Son Town, Bac Ninh Province
- Phone: +84-28-66865303  
- Mobile: +84 982 427 168
- Email: dung@ngocminh-ise.com
- Website: http://ngocminh-ise.com
You did not use the site, Click here to remain logged. Timeout: 60 second