SITRANS TO500 SITRANS TO500 The SITRANS TO500 multipoint measuring system is used for evaluating a large number of temperature measuring sensors arranged on a very narrow fiber-optic temperature measuring lance. The system consists of the following components: a read-out unit, the transmitter, and the measuring lance, which can each be connected to up to 48 temperature sensors on the transmitter at four channels. With up to four measuring probes, 192 measuring points can therefore be processed at the same time by a SITRANS TO500. The extremely thin sensor measuring probe of < 2 mm is used for measured value transmission. The system is therefore particularly suitable when the user wishes to install a very large number of measuring points in a tight space and with low thermal mass, such as in tube and tube bundle reactors or in capillary or microreactors. S000177 Temperature measurement Quantity: 0 đôi


  •  
  • SITRANS TO500

  • Post on 13-06-2019 09:51:43 PM - 1226 Views
  • The SITRANS TO500 multipoint measuring system is used for evaluating a large number of temperature measuring sensors arranged on a very narrow fiber-optic temperature measuring lance. The system consists of the following components: a read-out unit, the transmitter, and the measuring lance, which can each be connected to up to 48 temperature sensors on the transmitter at four channels. With up to four measuring probes, 192 measuring points can therefore be processed at the same time by a SITRANS TO500. The extremely thin sensor measuring probe of < 2 mm is used for measured value transmission. The system is therefore particularly suitable when the user wishes to install a very large number of measuring points in a tight space and with low thermal mass, such as in tube and tube bundle reactors or in capillary or microreactors.


The fast and gap-free detection of temperature profiles enables the plant operator to optimize processes in terms of lifetime, quality and output. Local overheating is quickly and accurately detected, thereby preventing damage to the process, plant and environment.

SITRANS TO500 technology is based on so-called fiber Bragg gratings (FBGs) which are arranged at individually defined points on the sensor probe. The transmitter sends light waves to the fiber-optic sensors and evaluates the reflected portions. In the transmitter, light is generated in the wavelength of 1500 to 1600 nm and output to the sensor measuring probe by means of a continuously tunable laser light. Each fiber Bragg grating reflects light of a defined wavelength. The wavelength reflected by the grating varies depending on the temperature. The reflection at the FBGs is thus a measure of the temperature at the respective measuring point. A gas cell with fixed absorption line serves as a reference in the SITRANS TO500 and the wavelength determination is continuously adjusted by it.

The transmitter provides the determined values for analysis in control systems via a Profibus DP interface and makes them available for management of the assets and optimization of the process. The parameters of the SITRANS TO500 are set via the integrated Ethernet interface.

Detail

Input

FBG (fiber Bragg grating) temperature measuring probes

4 channels

Measured variable

Temperature

Input type

FBG sensors (max. 48 per channel)

Characteristic curves

Temperature-linear

Resolution

0.1 K

Measuring accuracy

< 0.5 K

Repeatability

< 0.5 K

Measuring cycle

< 1 s

Measuring range

-180°C to +400°C, depending on measuring probe type

Unit

°C

Output

Output signal

PROFIBUS DP

Power supply

24 V DC ± 20%

Protection

Against reverse polarity

Measuring speed

 

Measuring rate

1 Hz, independent of the number of FBGs

Optical Power

≤ 1 mW per channel

Laser protection class

Class 1

Operating conditions

Ambient temperature

0 to +50°C

Storage temperature

-40 to +85°C

Relative humidity

< 80%, non condensing at 50°C

Electromagnetic compatibility

According to EN 61326

Housing

IP20

Construction

Weight

2.4 kg

Dimensions

250 x 140 x 110 mm

DIN rail adapter

At the back

Material

Aluminium

Displays and buttons

LEDs

"Power-on" (continuous light) 
"Status" (flashing during startup; otherwise continuous light)

Pushbutton

"Reset" (system restart or address reset)


 

Benefits

  • < 2 mm diameter of the measuring lance for more reactor space due to the smaller protective tube and thus faster response times

  • Gap-free temperature profile due to a total of 192 measuring points for process optimization

  • Simple insertion of the measuring probe into the protective tube due to the rolled state, as well as low-cost transport and easy installation

  • Flexible, application-specific customer solution through individual positioning of the FBGs on the sensor measuring probe

  • Measured value transfer takes place in the same fiber; no additional cables are necessary

  • Especially suitable for applications in which a large number of measuring points are to be installed in a very tight space and with low thermal mass

     

 

NGOC MINH ISE CO.,LTD
- HCMC Office: Block A, Lever 2, Linh Trung Building, No 6-8, Road no 16, Linh Trung Ward, Thu Duc City, HCMC.
- Head Quaters: 427 Le Dai Hanh, Ward 11, District 11, HCM City.
- Bac Ninh: Road TS5, Tien Son IZ, Tu Son Town, Bac Ninh Province
- Phone: +84-28-66865303  
- Mobile: +84 982 427 168
- Email: dung@ngocminh-ise.com
- Website: http://ngocminh-ise.com
You did not use the site, Click here to remain logged. Timeout: 60 second